4CE4

39S large subunit of the porcine mitochondrial ribosome


ELECTRON MICROSCOPY
Sample
39S MITOCHONDRIAL RIBOSOMAL SUBUNIT
Specimen Preparation
Sample Aggregation StatePARTICLE
Vitrification InstrumentHOMEMADE PLUNGER
Cryogen NameETHANE
Sample Vitrification DetailsMANUAL BLOTTING FOLLOWED BY MANUAL PLUNGING INTO LIQUID ETHANE
3D Reconstruction
Reconstruction MethodSINGLE PARTICLE
Number of Particles232181
Reported Resolution (Å)4.9
Resolution MethodFSC 0.143 CUT-OFF
Other DetailsRESOLUTION DETERMIED ACCORDING TO GOLD STANDARD FSC BY FSC EQUAL 0.143 CRITERION FROM TWO INDEPENDENTLY REFINED DATA HALF SETS
Refinement TypeHALF-MAPS REFINED INDEPENDENTLY
Symmetry TypePOINT
Point SymmetryC1
Map-Model Fitting and Refinement
Id1 (3V2D, 1R73, 2QYQ, 1QF6, 1O0W, 2CW9, 2XZN, 1J26, 1S3A)
Refinement SpaceREAL
Refinement ProtocolOTHER
Refinement Target
Overall B Value
Fitting Procedure
DetailsREFINEMENT PROTOCOL--X-RAY STRUCTURES, HOMOLOGY MODELS
Data Acquisition
Detector TypeFEI FALCON II (4k x 4k)
Electron Dose (electrons/Å**2)20
Imaging Experiment1
Date of Experiment
Temperature (Kelvin)79
Microscope ModelFEI TITAN KRIOS
Minimum Defocus (nm)1200
Maximum Defocus (nm)3600
Minimum Tilt Angle (degrees)
Maximum Tilt Angle (degrees)
Nominal CS2.7
Imaging ModeBRIGHT FIELD
Specimen Holder Model
Nominal Magnification59000
Calibrated Magnification
SourceFIELD EMISSION GUN
Acceleration Voltage (kV)300
Imaging DetailsIMAGES COLLECTED ON A FEI TITAN KRIOS BETWEEN NOVEMBER 2012 AND JUNE 2013. CALIBRATED MAGNIFICATION 141510 FOR FALCON II DATA AND 99290 FOR FALCON I DATA.
EM Software
TaskSoftware PackageVersion
CTF CORRECTIONCTFFIND3
MODEL FITTINGCoot
MODEL FITTINGO
MODEL FITTINGUCSF Chimera
RECONSTRUCTIONIMAGIC5
RECONSTRUCTIONRELION
RECONSTRUCTIONSPIDER
Image Processing
CTF Correction TypeCTF Correction DetailsNumber of Particles SelectedParticle Selection Details
PER DETECTOR FRAME