1PDF

Fitting of gp11 crystal structure into 3D cryo-EM reconstruction of bacteriophage T4 baseplate-tail tube complex


ELECTRON MICROSCOPY
Sample
T4 18-,23-
Sample Components
gp11
Specimen Preparation
Sample Aggregation StatePARTICLE
Vitrification Instrument
Cryogen NameETHANE
Sample Vitrification Detailsethane vitrification
3D Reconstruction
Reconstruction MethodSINGLE PARTICLE
Number of Particles945
Reported Resolution (Å)12
Resolution Method
Other Detailsa modified version of program SPIDER was used for the reconstruction
Refinement Type
Symmetry TypePOINT
Point SymmetryC6
Map-Model Fitting and Refinement
Id1 (1EL6)
Refinement SpaceREAL
Refinement ProtocolOTHER
Refinement TargetCorrelation coefficient maximum
Overall B Value
Fitting Procedure
DetailsREFINEMENT PROTOCOL--Laplacian-filtered real space
Data Acquisition
Detector TypeKODAK SO-163 FILM
Electron Dose (electrons/Å**2)25
Imaging Experiment1
Date of Experiment2001-01-30
Temperature (Kelvin)70
Microscope ModelFEI/PHILIPS CM300FEG/T
Minimum Defocus (nm)1200
Maximum Defocus (nm)5000
Minimum Tilt Angle (degrees)
Maximum Tilt Angle (degrees)
Nominal CS2
Imaging ModeBRIGHT FIELD
Specimen Holder Model
Nominal Magnification45000
Calibrated Magnification47000
SourceFIELD EMISSION GUN
Acceleration Voltage (kV)300
Imaging Details
EM Software
TaskSoftware PackageVersion
MODEL FITTINGSITUS COLORES2
RECONSTRUCTIONSPIDER
Image Processing
CTF Correction TypeCTF Correction DetailsNumber of Particles SelectedParticle Selection Details
CTF correction of each particle using Wiener filtering