7JSY

Proteinase K soaked with I3C determined by MicroED from a single milled microcrystal


ELECTRON CRYSTALLOGRAPHY

Crystal Data

Unit Cell
Length ( Å )Angle ( ˚ )
a = 67.555α = 90
b = 67.555β = 90
c = 102.773γ = 90
Symmetry
Space GroupP 43 21 2

Data Collection

Refinement

Statistics
Diffraction IDStructure Solution MethodCross Validation methodResolution (High)Resolution (Low)Cut-off Sigma (F)Number Reflections (Observed)Number Reflections (R-Free)Percent Reflections (Observed)R-Factor (Observed)R-WorkR-FreeMean Isotropic B
ELECTRON CRYSTALLOGRAPHYFREE R-VALUE1.7843.321.3422205144994.520.17210.16940.209413.51
Temperature Factor Modeling
Anisotropic B[1][1]Anisotropic B[1][2]Anisotropic B[1][3]Anisotropic B[2][2]Anisotropic B[2][3]Anisotropic B[3][3]
RMS Deviations
KeyRefinement Restraint Deviation
f_dihedral_angle_d6.8398
f_angle_d0.7631
f_chiral_restr0.045
f_bond_d0.0048
f_plane_restr0.0038
Non-Hydrogen Atoms Used in Refinement
Non-Hydrogen AtomsNumber
Protein Atoms2093
Nucleic Acid Atoms
Solvent Atoms246
Heterogen Atoms

Software

Software
Software NamePurpose
phenix.refinerefinement
PHENIXrefinement
Sample
Proteinase K
Specimen Preparation
Sample Aggregation State3D ARRAY
Vitrification Instrument
Cryogen NameETHANE
Sample Vitrification Details
3D Reconstruction
Reconstruction MethodCRYSTALLOGRAPHY
Number of Particles
Reported Resolution (Å)1.78
Resolution MethodDIFFRACTION PATTERN/LAYERLINES
Other Details
Refinement Type
Symmetry Type3D CRYSTAL
Space Group Name
Length a67.55
Length b67.55
Length c67.55
Angle Alpha90
Angle Beta90
Angle Gamma90
Map-Model Fitting and Refinement
Id1 (6CL7)
Refinement SpaceRECIPROCAL
Refinement ProtocolRIGID BODY FIT
Refinement Targetmaximum liklihood
Overall B Value13.51
Fitting Procedure
Details
Data Acquisition
Detector TypeFEI CETA (4k x 4k)
Electron Dose (electrons/Å**2)0.01
Imaging Experiment1
Date of Experiment
Temperature (Kelvin)
Microscope ModelTFS TALOS
Minimum Defocus (nm)
Maximum Defocus (nm)
Minimum Tilt Angle (degrees)
Maximum Tilt Angle (degrees)
Nominal CS
Imaging ModeDIFFRACTION
Specimen Holder ModelFEI TITAN KRIOS AUTOGRID HOLDER
Nominal Magnification
Calibrated Magnification
SourceFIELD EMISSION GUN
Acceleration Voltage (kV)200
Imaging DetailsTilt series: -30 to +30, 0.25 deg/sec, 1 sec readout
Image Processing
CTF Correction TypeCTF Correction DetailsNumber of Particles SelectedParticle Selection Details
NONE