6QM7

Leishmania tarentolae proteasome 20S subunit complexed with GSK3494245


ELECTRON MICROSCOPY

Refinement

RMS Deviations
KeyRefinement Restraint Deviation
r_dihedral_angle_2_deg35.235
r_dihedral_angle_3_deg20.777
r_dihedral_angle_4_deg17.586
r_long_range_B_refined9.04
r_long_range_B_other9.039
r_dihedral_angle_1_deg7.897
r_scangle_other6.427
r_mcangle_it4.583
r_mcangle_other4.583
r_scbond_it3.678
RMS Deviations
KeyRefinement Restraint Deviation
r_dihedral_angle_2_deg35.235
r_dihedral_angle_3_deg20.777
r_dihedral_angle_4_deg17.586
r_long_range_B_refined9.04
r_long_range_B_other9.039
r_dihedral_angle_1_deg7.897
r_scangle_other6.427
r_mcangle_it4.583
r_mcangle_other4.583
r_scbond_it3.678
r_scbond_other3.678
r_mcbond_it2.733
r_mcbond_other2.733
r_angle_refined_deg1.483
r_angle_other_deg1.237
r_chiral_restr0.063
r_bond_refined_d0.008
r_gen_planes_refined0.006
r_bond_other_d0.002
r_gen_planes_other0.002
r_nbd_refined
r_nbd_other
r_nbtor_refined
r_nbtor_other
r_xyhbond_nbd_refined
r_xyhbond_nbd_other
r_metal_ion_refined
r_metal_ion_other
r_symmetry_vdw_refined
r_symmetry_vdw_other
r_symmetry_hbond_refined
r_symmetry_hbond_other
r_symmetry_metal_ion_refined
r_symmetry_metal_ion_other
r_scangle_it
r_rigid_bond_restr
r_sphericity_free
r_sphericity_bonded
Sample
Proteasome 20S subunit
Specimen Preparation
Sample Aggregation StatePARTICLE
Vitrification Instrument
Cryogen NameETHANE
Sample Vitrification Details
3D Reconstruction
Reconstruction MethodSINGLE PARTICLE
Number of Particles182775
Reported Resolution (Å)2.8
Resolution MethodFSC 0.143 CUT-OFF
Other Details
Refinement Type
Symmetry TypePOINT
Point SymmetryC1
Map-Model Fitting and Refinement
Id1 (4R3O)
Refinement Space
Refinement ProtocolFLEXIBLE FIT
Refinement Target
Overall B Value
Fitting Procedure
Details
Data Acquisition
Detector TypeFEI FALCON III (4k x 4k)
Electron Dose (electrons/Å**2)30
Imaging Experiment1
Date of Experiment
Temperature (Kelvin)
Microscope ModelFEI TITAN KRIOS
Minimum Defocus (nm)
Maximum Defocus (nm)
Minimum Tilt Angle (degrees)
Maximum Tilt Angle (degrees)
Nominal CS
Imaging ModeBRIGHT FIELD
Specimen Holder Model
Nominal Magnification
Calibrated Magnification
SourceFIELD EMISSION GUN
Acceleration Voltage (kV)300
Imaging Details
EM Software
TaskSoftware PackageVersion
MODEL FITTINGCoot
MODEL REFINEMENTREFMAC
RECONSTRUCTIONRELION2.1
Image Processing
CTF Correction TypeCTF Correction DetailsNumber of Particles SelectedParticle Selection Details
PHASE FLIPPING AND AMPLITUDE CORRECTION