6EGV

Sacbrood virus of honeybee


ELECTRON MICROSCOPY

Refinement

RMS Deviations
KeyRefinement Restraint Deviation
r_dihedral_angle_2_deg30.486
r_dihedral_angle_3_deg11.677
r_dihedral_angle_4_deg9.805
r_dihedral_angle_1_deg5.401
r_long_range_B_refined1.411
r_long_range_B_other1.411
r_angle_refined_deg0.933
r_mcangle_it0.666
r_mcangle_other0.666
r_angle_other_deg0.603
RMS Deviations
KeyRefinement Restraint Deviation
r_dihedral_angle_2_deg30.486
r_dihedral_angle_3_deg11.677
r_dihedral_angle_4_deg9.805
r_dihedral_angle_1_deg5.401
r_long_range_B_refined1.411
r_long_range_B_other1.411
r_angle_refined_deg0.933
r_mcangle_it0.666
r_mcangle_other0.666
r_angle_other_deg0.603
r_mcbond_it0.349
r_mcbond_other0.349
r_scangle_other0.344
r_scbond_it0.153
r_scbond_other0.153
r_chiral_restr0.038
r_bond_refined_d0.004
r_gen_planes_refined0.002
r_bond_other_d0.001
r_gen_planes_other0.001
r_nbd_refined
r_nbd_other
r_nbtor_refined
r_nbtor_other
r_xyhbond_nbd_refined
r_xyhbond_nbd_other
r_metal_ion_refined
r_metal_ion_other
r_symmetry_vdw_refined
r_symmetry_vdw_other
r_symmetry_hbond_refined
r_symmetry_hbond_other
r_symmetry_metal_ion_refined
r_symmetry_metal_ion_other
r_scangle_it
r_rigid_bond_restr
r_sphericity_free
r_sphericity_bonded
Sample
Sacbrood virus
Specimen Preparation
Sample Aggregation StatePARTICLE
Vitrification InstrumentFEI VITROBOT MARK II
Cryogen NameETHANE
Sample Vitrification Details
3D Reconstruction
Reconstruction MethodSINGLE PARTICLE
Number of Particles13148
Reported Resolution (Å)3.18
Resolution MethodFSC 0.143 CUT-OFF
Other Details
Refinement Type
Symmetry TypePOINT
Map-Model Fitting and Refinement
Id1
Refinement SpaceREAL
Refinement ProtocolRIGID BODY FIT
Refinement TargetR-factor
Overall B Value47.1
Fitting Procedure
Details
Data Acquisition
Detector TypeFEI FALCON II (4k x 4k)
Electron Dose (electrons/Å**2)21
Imaging Experiment1
Date of Experiment
Temperature (Kelvin)
Microscope ModelFEI TITAN KRIOS
Minimum Defocus (nm)1000
Maximum Defocus (nm)4000
Minimum Tilt Angle (degrees)
Maximum Tilt Angle (degrees)
Nominal CS2.7
Imaging ModeBRIGHT FIELD
Specimen Holder ModelFEI TITAN KRIOS AUTOGRID HOLDER
Nominal Magnification75000
Calibrated Magnification74325
SourceFIELD EMISSION GUN
Acceleration Voltage (kV)300
Imaging DetailsPreliminar grid screening was performed manually on FEI Tecnai F20 (cryo stage).
EM Software
TaskSoftware PackageVersion
IMAGE ACQUISITIONEPU
CTF CORRECTIONGctf
MODEL FITTINGCoot
MODEL REFINEMENTPHENIX
FINAL EULER ASSIGNMENTRELION2
CLASSIFICATIONRELION2
RECONSTRUCTIONRELION2
Image Processing
CTF Correction TypeCTF Correction DetailsNumber of Particles SelectedParticle Selection Details
PHASE FLIPPING AND AMPLITUDE CORRECTION51000Full virions were selected together with empty particles from the same set of micrographs. Subsequent 2D classification sorted the particles of two types. Full and empty particles were further reconstructed separately.