5Z1L

Cryo-EM structure of Methanoccus maripaludis archaellum


ELECTRON MICROSCOPY

Refinement

RMS Deviations
KeyRefinement Restraint Deviation
f_dihedral_angle_d4.358
f_angle_d0.969
f_chiral_restr0.069
f_plane_restr0.006
f_bond_d0.004
Sample
M.maripaludis archaellin FlaB1 filament
Specimen Preparation
Sample Aggregation StatePARTICLE
Vitrification InstrumentFEI VITROBOT MARK IV
Cryogen NameETHANE
Sample Vitrification Details3 second blot, 3.5uL
3D Reconstruction
Reconstruction MethodHELICAL
Number of Particles110747
Reported Resolution (Å)4
Resolution MethodFSC 0.143 CUT-OFF
Other Details
Refinement Type
Symmetry TypePOINT
Axial SymmetryC1
Axial Rise5.7
Angular Rotation108.2
Map-Model Fitting and Refinement
Id1
Refinement SpaceREAL
Refinement ProtocolFLEXIBLE FIT
Refinement Target
Overall B Value
Fitting Procedure
Details
Data Acquisition
Detector TypeGATAN K2 SUMMIT (4k x 4k)
Electron Dose (electrons/Å**2)96
Imaging Experiment1
Date of Experiment
Temperature (Kelvin)
Microscope ModelFEI TITAN KRIOS
Minimum Defocus (nm)-1500
Maximum Defocus (nm)-2500
Minimum Tilt Angle (degrees)
Maximum Tilt Angle (degrees)
Nominal CS2.7
Imaging ModeBRIGHT FIELD
Specimen Holder ModelFEI TITAN KRIOS AUTOGRID HOLDER
Nominal Magnification105000
Calibrated Magnification47619
SourceFIELD EMISSION GUN
Acceleration Voltage (kV)300
Imaging Detailsnanoprobe, parallel beam illumination
EM Software
TaskSoftware PackageVersion
PARTICLE SELECTIONEMAN22.1
IMAGE ACQUISITIONLeginon3.2
CTF CORRECTIONCTFFIND4.1
MODEL FITTINGCoot
INITIAL EULER ASSIGNMENTSPRING0.84
FINAL EULER ASSIGNMENTSPRING0.84
CLASSIFICATIONSPRING0.84
RECONSTRUCTIONSPRING0.84
MODEL REFINEMENTPHENIX
Image Processing
CTF Correction TypeCTF Correction DetailsNumber of Particles SelectedParticle Selection Details
PHASE FLIPPING AND AMPLITUDE CORRECTIONdeconvolution in SPRING110747