5Z10

Structure of the mechanosensitive Piezo1 channel


ELECTRON MICROSCOPY

Refinement

RMS Deviations
KeyRefinement Restraint Deviation
f_dihedral_angle_d10.107
f_angle_d1.029
f_chiral_restr0.059
f_plane_restr0.008
f_bond_d0.006
Sample
Cryo-EM map of the mechanosensitive Piezo1 channel
Specimen Preparation
Sample Aggregation StatePARTICLE
Vitrification InstrumentFEI VITROBOT MARK IV
Cryogen NameETHANE
Sample Vitrification DetailsAfter a 15 sec waiting time, the grids were blotted for 3.5 sec and plunged into liquid ethane
3D Reconstruction
Reconstruction MethodSINGLE PARTICLE
Number of Particles238529
Reported Resolution (Å)3.97
Resolution MethodFSC 0.143 CUT-OFF
Other Details
Refinement Type
Symmetry TypePOINT
Point SymmetryC3
Map-Model Fitting and Refinement
Id1
Refinement Space
Refinement Protocol
Refinement Target
Overall B Value
Fitting Procedure
Details
Data Acquisition
Detector TypeGATAN K2 SUMMIT (4k x 4k)
Electron Dose (electrons/Å**2)50
Imaging Experiment1
Date of Experiment
Temperature (Kelvin)
Microscope ModelFEI TITAN KRIOS
Minimum Defocus (nm)1500
Maximum Defocus (nm)
Minimum Tilt Angle (degrees)
Maximum Tilt Angle (degrees)
Nominal CS2.7
Imaging ModeBRIGHT FIELD
Specimen Holder ModelFEI TITAN KRIOS AUTOGRID HOLDER
Nominal Magnification22500
Calibrated Magnification
SourceFIELD EMISSION GUN
Acceleration Voltage (kV)300
Imaging Details
EM Software
TaskSoftware PackageVersion
IMAGE ACQUISITIONUCSFImage4
CTF CORRECTIONRELION1.4
INITIAL EULER ASSIGNMENTRELION1.4
FINAL EULER ASSIGNMENTRELION1.4
CLASSIFICATIONRELION1.4
RECONSTRUCTIONRELION1.4
Image Processing
CTF Correction TypeCTF Correction DetailsNumber of Particles SelectedParticle Selection Details
PHASE FLIPPING AND AMPLITUDE CORRECTION