4D2Q

Negative-stain electron microscopy of E. coli ClpB mutant E432A (BAP form bound to ClpP)


ELECTRON MICROSCOPY
Sample
BAP FORM OF CLPB E432A REPRESSED MUTANT WITH ATPGS
Specimen Preparation
Sample Aggregation StatePARTICLE
Staining TypeNEGATIVE
Staining Materialuranyl acetate
Staining Details
3D Reconstruction
Reconstruction MethodSINGLE PARTICLE
Number of Particles11570
Reported Resolution (Å)18
Resolution Method
Other DetailsSUBMISSION BASED ON EXPERIMENTAL DATA FROM EMDB EMD-2555. (DEPOSITION ID: 12235).
Refinement Type
Symmetry TypePOINT
Point SymmetryC6
Data Acquisition
Detector TypeGATAN K2 (4k x 4k)
Electron Dose (electrons/Å**2)20
Imaging Experiment1
Date of Experiment2011-06-06
Temperature (Kelvin)
Microscope ModelFEI TECNAI F20
Minimum Defocus (nm)500
Maximum Defocus (nm)1200
Minimum Tilt Angle (degrees)
Maximum Tilt Angle (degrees)
Nominal CS2
Imaging ModeBRIGHT FIELD
Specimen Holder Model
Nominal Magnification50000
Calibrated Magnification68000
SourceFIELD EMISSION GUN
Acceleration Voltage (kV)200
Imaging Details
EM Software
TaskSoftware PackageVersion
MODEL FITTINGUCSF Chimera
RECONSTRUCTIONIMAGIC
RECONSTRUCTIONSPIDER
Image Processing
CTF Correction TypeCTF Correction DetailsNumber of Particles SelectedParticle Selection Details
PHASE FLIPPING ENTIRE FRAME