4CBF

Near-atomic resolution cryo-EM structure of Dengue serotype 4 virus


ELECTRON MICROSCOPY
Sample
MATURE DENGUE VIRUS SEROTYPE 4
Specimen Preparation
Sample Aggregation StatePARTICLE
Vitrification InstrumentFEI VITROBOT MARK IV
Cryogen NameETHANE
Sample Vitrification DetailsLIQUID ETHANE
3D Reconstruction
Reconstruction MethodSINGLE PARTICLE
Number of Particles16602
Reported Resolution (Å)4.1
Resolution Method
Other DetailsMPSA SUBMISSION BASED ON EXPERIMENTAL DATA FROM EMDB EMD-2485. (DEPOSITION ID: 12027).
Refinement Type
Symmetry TypePOINT
Point SymmetryI
Map-Model Fitting and Refinement
Id1 (3J27)
Refinement SpaceREAL
Refinement ProtocolFLEXIBLE FIT
Refinement TargetREAL SPACE CORRELATION
Overall B Value
Fitting Procedure
DetailsMETHOD--FLEXIBLE REFINEMENT PROTOCOL--CRYO-EM
Data Acquisition
Detector TypeFEI FALCON I (4k x 4k)
Electron Dose (electrons/Å**2)18
Imaging Experiment1
Date of Experiment2012-04-14
Temperature (Kelvin)100
Microscope ModelFEI TITAN KRIOS
Minimum Defocus (nm)500
Maximum Defocus (nm)3500
Minimum Tilt Angle (degrees)
Maximum Tilt Angle (degrees)
Nominal CS2.7
Imaging ModeBRIGHT FIELD
Specimen Holder Model
Nominal Magnification125000
Calibrated Magnification129629
SourceFIELD EMISSION GUN
Acceleration Voltage (kV)300
Imaging Details
EM Software
TaskSoftware PackageVersion
MODEL FITTINGCNS
MODEL FITTINGCoot
MODEL FITTINGUCSF Chimera
RECONSTRUCTIONEMAN1
RECONSTRUCTIONEMAN2
RECONSTRUCTIONMPSA
Image Processing
CTF Correction TypeCTF Correction DetailsNumber of Particles SelectedParticle Selection Details
EACH PARTICLE