3IXZ

Pig gastric H+/K+-ATPase complexed with aluminium fluoride


ELECTRON CRYSTALLOGRAPHY

Crystallization

Crystalization Experiments
IDMethodpHTemperatureDetails
1MICRODIALYSIS4.8720 mM propionate, 1 mM MgCl2, 0.5 mM AlCl3, 4 mM NaF, 0.3 mM ADP, 3 mM DTT, 10% (w/v) glycerol, pH 4.87, MICRODIALYSIS

Crystal Data

Unit Cell
Length ( Å )Angle ( ˚ )
a = 140.4α = 90
b = 109β = 90
c = 320γ = 90
Symmetry
Space GroupP 21 21 2

Diffraction

Diffraction Experiment
ID #Crystal IDScattering TypeData Collection TemperatureDetectorDetector TypeDetailsCollection DateMonochromatorProtocol
11electron4.22008-04-15MSINGLE WAVELENGTH

Data Collection

Refinement

Non-Hydrogen Atoms Used in Refinement
Non-Hydrogen AtomsNumber
Protein Atoms1044
Nucleic Acid Atoms
Solvent Atoms
Heterogen Atoms

Software

Software
Software NamePurpose
MRCmodel building
MRCphasing
Sample
HK-ATPase
Sample Components
HK-ATPase alpha subunit
HK-ATPase beta subunit
Specimen Preparation
Sample Aggregation State2D ARRAY
Vitrification InstrumentREICHERT-JUNG PLUNGER
Cryogen NameNITROGEN
Sample Vitrification Details
3D Reconstruction
Reconstruction MethodCRYSTALLOGRAPHY
Number of Particles
Reported Resolution (Å)6.5
Resolution Method
Other Details
Refinement Type
Symmetry Type2D CRYSTAL
Map-Model Fitting and Refinement
Id1 (3B8E)2 (3B8E)
Refinement SpaceREALREAL
Refinement ProtocolRIGID BODY FITRIGID BODY FIT
Refinement TargetCross-correlation coefficientCross-correlation coefficient
Overall B Value
Fitting Procedure
DetailsMETHOD--Local refinement REFINEMENT PROTOCOL--rigid bodyMETHOD--Local refinement REFINEMENT PROTOCOL--rigid body
Data Acquisition
Detector TypeKODAK SO-163 FILM
Electron Dose (electrons/Å**2)25
Imaging Experiment1
Date of Experiment
Temperature (Kelvin)4.2
Microscope ModelJEOL KYOTO-3000SFF
Minimum Defocus (nm)3480
Maximum Defocus (nm)390
Minimum Tilt Angle (degrees)
Maximum Tilt Angle (degrees)73.3
Nominal CS1.6
Imaging ModeBRIGHT FIELD
Specimen Holder Model
Nominal Magnification6000
Calibrated Magnification59100
SourceFIELD EMISSION GUN
Acceleration Voltage (kV)300
Imaging Details
EM Software
TaskSoftware PackageVersion
MODEL FITTINGSitus
RECONSTRUCTIONMRC
Image Processing
CTF Correction TypeCTF Correction DetailsNumber of Particles SelectedParticle Selection Details
Each images were CTF corrected.