3J3O

Conformational Shift of a Major Poliovirus Antigen Confirmed by Immuno-Cryogenic Electron Microscopy: 160S Poliovirus and C3-Fab Complex


ELECTRON MICROSCOPY
Sample
Poliovirus 160S particle and C3 Fab complex
Specimen Preparation
Sample Aggregation StatePARTICLE
Vitrification Instrument
Cryogen NameETHANE
Sample Vitrification DetailsVitrification carried out in ambient atmosphere. Ethane cooled by liquid nitrogen.
3D Reconstruction
Reconstruction MethodSINGLE PARTICLE
Number of Particles4184
Reported Resolution (Å)11.1
Resolution MethodFSC 0.5 CUT-OFF
Other DetailsReconstruction computed from focal pairs. Pairs not summed for reconstruction calculation.
Refinement Type
Symmetry TypePOINT
Point SymmetryI
Map-Model Fitting and Refinement
Id1 (1FPT, 1FPT, 1FPT)2 (1ASJ)
Refinement SpaceREALREAL
Refinement ProtocolRIGID BODY FITRIGID BODY FIT
Refinement Target
Overall B Value
Fitting Procedure
DetailsREFINEMENT PROTOCOL--Rigid Body DETAILS--Atomic coordinates for C3 Fab (Nature Struct. Biol. 2, 232-243) (PDB entry 1FPT) were manually fitted using ...REFINEMENT PROTOCOL--Rigid Body DETAILS--Atomic coordinates for C3 Fab (Nature Struct. Biol. 2, 232-243) (PDB entry 1FPT) were manually fitted using UCSF Chimera (Journal of Computational Chemistry 25, 1605-1612). A core-weighted, rigid-body fitting algorithm implemented in CHARRM (J Struct Biol 141, 63-76) was used to refine the fit.
REFINEMENT PROTOCOL--Rigid body DETAILS--The unmodified coordinates of PDB entry 1ASJ were placed into the cryo-EM density. The BC loop of VP1 was th ...REFINEMENT PROTOCOL--Rigid body DETAILS--The unmodified coordinates of PDB entry 1ASJ were placed into the cryo-EM density. The BC loop of VP1 was then modified based on the fitting (see primary citation for details).
Data Acquisition
Detector TypeKODAK SO-163 FILM
Electron Dose (electrons/Å**2)14
Imaging Experiment1
Date of Experiment
Temperature (Kelvin)
Microscope ModelFEI/PHILIPS CM200FEG
Minimum Defocus (nm)730
Maximum Defocus (nm)1770
Minimum Tilt Angle (degrees)
Maximum Tilt Angle (degrees)
Nominal CS2
Imaging ModeBRIGHT FIELD
Specimen Holder ModelGATAN LIQUID NITROGEN
Nominal Magnification38000
Calibrated Magnification37587
SourceFIELD EMISSION GUN
Acceleration Voltage (kV)120
Imaging Details
EM Software
TaskSoftware PackageVersion
MODEL FITTINGCHARMM
RECONSTRUCTIONEM3DR2
Image Processing
CTF Correction TypeCTF Correction DetailsNumber of Particles SelectedParticle Selection Details
CTF and decay correction of each particle