3J2W

Electron cryo-microscopy of Chikungunya virus


ELECTRON MICROSCOPY
Sample
Chikungunya VLP
Specimen Preparation
Sample Aggregation StatePARTICLE
Vitrification InstrumentFEI VITROBOT MARK I
Cryogen NameETHANE
Sample Vitrification DetailsBlot for 2 seconds before plunging into liquid ethane (FEI VITROBOT MARK I)
3D Reconstruction
Reconstruction MethodSINGLE PARTICLE
Number of Particles36236
Reported Resolution (Å)5
Resolution MethodFSC 0.5 CUT-OFF
Other Details(Single particle--Applied symmetry: I)
Refinement Type
Symmetry TypePOINT
Point SymmetryI
Map-Model Fitting and Refinement
Id1 (3N43)
Refinement SpaceRECIPROCAL
Refinement ProtocolRIGID BODY FIT
Refinement Target
Overall B Value
Fitting Procedure
DetailsREFINEMENT PROTOCOL--rigid body
Data Acquisition
Detector TypeGENERIC FILM
Electron Dose (electrons/Å**2)25
Imaging Experiment1
Date of Experiment2011-01-01
Temperature (Kelvin)
Microscope ModelFEI TITAN KRIOS
Minimum Defocus (nm)
Maximum Defocus (nm)
Minimum Tilt Angle (degrees)
Maximum Tilt Angle (degrees)
Nominal CS2.7
Imaging ModeBRIGHT FIELD
Specimen Holder ModelFEI TITAN KRIOS AUTOGRID HOLDER
Nominal Magnification59000
Calibrated Magnification
SourceFIELD EMISSION GUN
Acceleration Voltage (kV)300
Imaging Details
EM Software
TaskSoftware PackageVersion
MODEL FITTINGEMfit
RECONSTRUCTIONEMAN
RECONSTRUCTIONFREALIGN
Image Processing
CTF Correction TypeCTF Correction DetailsNumber of Particles SelectedParticle Selection Details
each particle